banner

School Laboratory Fume Hood

Materials
1.0 mm cold-rolled steel sheet
Airflow Technology
Adopts multi-duct laminar flow air supply
Make-up air ratio: 60%
Air Volume Parameter
Standard height: exhaust air flow 220-360 m³/h
Qualified air leakage rate, energy-saving
Basic Cabinet Configuration
Standard: two double-door storage cabinets
Support frame-type structural upgrade
Optional Accessories
Fireproof chemical cabinet / waste liquid cabinet / waste bin
Guarantee lab safety & sanitation
Ventilation Connection
Upper & lower cabinets all connectable to exhaust system
Send Inquiry Download
  • Product Description

School Laboratory Fume Hood: Professional Safety Solution for Educational Environments

At Luoyang Youken Laboratory Equipment Co., Ltd., we make high-performance School Laboratory Fume Hood units particularly designed for instructive educate. Our rage hoods are built from strong 1.0 mm cold-rolled steel and highlight progressed multi-duct laminar stream discuss supply innovation with a 60% make-up discuss proportion. With standard deplete discuss stream extending from 220-360 m³/h, your understudies advantage from qualified discuss spillage rates and energy-saving operation.

Backed by our 30,000 m² generation office and a group of 100 proficient engineers, we provide research facility security gear that meets ISO, CE, SEFA, and SGS worldwide quality benchmarks. Each unit comes standard with two double-door capacity cabinets and underpins frame-type auxiliary overhauls to coordinate your particular instructing requirements.

School Laboratory Fume Hood

Why Choose Our Educational Fume Hoods?

Your school merits security gear that equalizations security with common sense. Our School Laboratory Fume Hood frameworks are purpose-built for educating situations where understudy security comes first.

The adjusted edges on all our units ensure understudies amid hands-on tests. You won't discover sharp corners that posture harm dangers amid active lab sessions. This keen plan detail things when numerous understudies work at the same time in limited spaces.

Durability characterizes each component we make. The vigorous development withstands a long time of every day utilize over chemistry, science, and material science educational program. You'll appreciate the basic upkeep necessities that keep operational costs reasonable for your institution.

Our ventilation association plan permits both upper and lower cabinets to coordinated consistently with your existing deplete framework. This adaptability implies simpler establishment and superior wind stream administration over your whole research facility space.

Technical Specifications

ParameterDetails
Material1.0 mm cold-rolled steel sheet
Airflow TechnologyMulti-duct laminar flow air supply
Make-up Air Ratio60%
Exhaust Air Flow220-360 m³/h (standard height)
Available SizesL1200×D850×H2350 mm
L1500×D850×H2350 mm
L1800×D850×H2350 mm
Standard CabinetTwo double-door storage cabinets
Structural OptionsFrame-type upgrade available
Optional AccessoriesFireproof chemical cabinet
Waste liquid cabinet
Waste bin
VentilationUpper & lower cabinets connectable to exhaust

Safety Features That Protect Your Students

Student safety drives every design decision in our educational Fume Hoods. The multi-duct laminar flow technology ensures consistent air distribution that eliminates dead zones where hazardous vapors might accumulate.

Your facility benefits from our qualified air leakage rate testing. We verify containment performance before every unit leaves our 30,000 m² manufacturing facility. This quality control process guarantees the protection your students need during chemical experiments.

The 60% make-up air ratio creates negative pressure inside the working chamber. Hazardous fumes get captured and expelled before they reach breathing zones. This engineering approach follows established safety protocols recognized across educational institutions worldwide.

Energy efficiency doesn't compromise safety in our designs. The optimized airflow range of 220-360 m³/h provides adequate ventilation while controlling operational costs. You'll reduce utility expenses without sacrificing the protective environment your students require.

Customization Options for Your Laboratory

Every educational institution has unique space constraints and curriculum requirements. We offer three standard sizes to accommodate different laboratory layouts and student group sizes.

The L1200 model fits compact teaching labs where space optimization matters. Mid-sized L1500 units balance workspace with footprint efficiency. Our L1800 configuration provides generous working area for complex experiments requiring multiple apparatus setups.

Frame-type structural upgrades transform the basic cabinet into a more robust support system. This option suits institutions planning long-term use or handling heavier equipment during advanced chemistry demonstrations.

Optional accessories extend functionality beyond basic containment. Add fireproof chemical cabinets for safe reagent storage directly within your fume hood system. Waste liquid cabinets and waste bins integrate sanitation protocols into your laboratory workflow, ensuring compliance with safety regulations.

One-stop source factory for lab furniture

Application Scenarios in Educational Settings

Our School Laboratory Fume Hood excels across multiple teaching environments. Secondary school chemistry programs rely on our units for safe demonstration of fundamental reactions. The durable construction withstands the enthusiastic handling that comes with introducing students to laboratory practices.

University undergraduate programs demand more from their equipment. Your organic chemistry courses involve extended solvent use and acid handling. Our hoods feature chemical-resistant interiors designed specifically for these rigorous applications.

STEM programs benefit from the versatility built into every unit. Whether you're conducting biology dissections, chemistry syntheses, or physics demonstrations involving reactive materials, the consistent airflow protects participants from exposure.

Research projects in educational institutions require reliable containment over extended periods. Students working on independent studies need equipment that performs consistently throughout semester-long investigations. Our manufacturing quality ensures dependable operation that supports academic achievement.

Application Scenarios in Educational Settings

Maintenance and Long-Term Value

Simple maintenance procedures keep your fume hoods operating at peak performance. The cold-rolled steel construction resists corrosion from common laboratory chemicals. You won't face frequent replacement costs that burden institutional budgets.

Regular filter inspections and airflow verification form the core of your maintenance routine. We design our systems for straightforward access to components requiring periodic attention. Your facilities team can complete standard maintenance without specialized training or expensive service contracts.

The dual storage cabinets organize chemicals and equipment efficiently. Proper storage within the fume hood system reduces clutter in your laboratory space. Students develop better organizational habits when equipment design supports proper practices.

Ventilation connectivity to both upper and lower cabinets maximizes your exhaust system efficiency. This design feature becomes especially valuable when managing multiple fume hoods within a single laboratory space. You'll achieve better air balance and more consistent performance across all units.

Frequently Asked Questions

Q: Should schools choose ducted or ductless fume hood models?

A: Ducted hoods work best for universal chemical use and high-heat experiments. They provide superior containment for diverse curricula. Ductless models suit mobile classrooms and specific low-toxicity applications where duct installation costs become prohibitive for your budget.

Q: What is the ideal face velocity for student safety?

A: Industry standards recommend 0.5 m/s (100 fpm) for general educational use. High-performance low-flow hoods can operate safely at 0.3 m/s (60 fpm) when equipped with proper baffle design. Your specific curriculum requirements help determine the optimal velocity.

Q: How often does a product require certification?

A: ASHRAE 110 and OSHA standards mandate comprehensive performance testing at least once every 12 months. Regular certification ensures your equipment continues protecting students throughout its service life.

Q: Are glass-sided hoods safe for chemistry applications?

A: Yes, when manufactured with 6mm or thicker tempered safety glass or laminated glass. These materials provide excellent visibility for instructional demonstrations while maintaining impact resistance during normal laboratory operations.

Q: What liner material works best for high-acid environments?

A: Phenolic resin serves as the standard liner material for most educational applications. Polypropylene (PP) liners offer superior resistance for heavy inorganic acid use common in advanced university laboratory courses. We help you select the appropriate material based on your specific chemical inventory.

Ready to Upgrade Your Laboratory Safety?

Our Team of 100 engineers stands ready to support your institution's specific requirements for School Laboratory Fume Hood.

Contact Us today at ceo@ukenlab.com.

Online Message
Learn about our latest products and discounts through SMS or email