banner

Stainless Steel Fume Hood

System Compatibility
Compatible with VAV variable air volume systems
Integrates ventilation, exhaust, experiment & storage functions
Material & Application
Corrosion-resistant & easy-clean materials
Suitable for lab volatile chemical gas treatment
Structural Merit
Practical layout, convenient for daily maintenance
Maintenance Convenience
Detachable front frame & side panels
Side service door for easy access
Flexible layout for water, power and gas piping
Send Inquiry Download
  • Product Description

Stainless Steel Fume Hood – Premium Laboratory Safety Solution

Luoyang Youken Laboratory Equipment Co., Ltd. conveys enterprise-grade Stainless Steel Fume Hood arrangements built for requesting research facility situations. Made in our 30,000 m² generation office by 100 proficient engineers, each unit highlights corrosion-resistant development consistent with VAV variable discuss volume frameworks. Our item coordinating ventilation, deplete, try, and capacity capacities into one down to earth format. The separable front outline and side boards empower helpful support get to, whereas adaptable channeling courses of action oblige assorted water, control, and gas prerequisites for pharmaceutical, chemical, and organic inquire about applications.

Stainless Steel Fume Hood

Why Choose Stainless Steel Construction for Your Lab?

Traditional smolder hoods frequently battle with chemical introduction and stickiness. Steel development offers particular points of interest that address genuine research facility challenges.

The non-porous surface anticipates chemical assimilation and defilement buildup. You won't confront the debasement issues common with coated materials or laminates.

High-grade stainless fabric withstands forceful cleaning conventions. Your group can utilize thorough cleaning strategies without stressing almost surface damage.

Heat resistance makes these units perfect for high-temperature responses. The fabric keeps up auxiliary judgment indeed beneath warm push that would compromise other options.

Technical Specifications

ParameterSpecification
Model OptionsL1200×D850×H2350 mm
 L1500×D850×H2350 mm
 L1800×D850×H2350 mm
Material GradeAISI 304/316L Stainless Steel
System TypeVAV Compatible
Surface FinishSmooth, Easy-Clean
Worktop DesignOne-Piece Seamless Construction
Access FeaturesDetachable Front Frame & Side Panels
Service DoorSide-Mounted for Maintenance
Corrosion ResistanceHigh-Grade for Volatile Chemicals

Core Performance Benefits

Our Stainless Steel Fume Hood deliver quantifiable preferences for research facility operations. Each include addresses particular workflow requirements.

Superior Durability

The smooth surface stands up to recoloring and disentangles every day cleaning schedules. Your support staff spares time whereas guaranteeing cleanliness standards.

Rust and Erosion Protection

Humid research facility situations request strong materials. This development keeps up execution in conditions that cause conventional units to fall apart rapidly.

Leak-Free Workspace

The one-piece worktop dispenses with crease vulnerabilities. You pick up peace of intellect knowing perilous materials won't enter work surfaces.

Maintenance Accessibility

Side benefit entryways and detachable boards decrease downtime. Specialists get to plumbing and electrical frameworks rapidly without disturbing adjoining workstations.

Core Performance Benefits

Applications Across Industries

These ventilation frameworks serve different logical segments. Your office benefits from demonstrated arrangements utilized worldwide.

Pharmaceutical Research

Handle dynamic pharmaceutical fixings securely. The fabric won't respond with compounds or compromise item virtue amid definition development.

Chemical Examination Labs

Process unstable substances with certainty. Erosion resistance handles forceful reagents that harm routine equipment.

Medical Diagnostics

Maintain sterile conditions for touchy testing. The non-porous surface avoids microbial development and cross-contamination between samples.

Educational Institutions

Provide understudies with professional-grade hardware. Strong development withstands overwhelming utilize whereas educating legitimate security protocols.

Applications Across Industries

Quality Standards and Certifications

Luoyang Youken holds ISO, CE, SEFA, and SGS certifications. Our quality control processes ensure every unit meets international safety requirements.

Each Stainless Steel Fume Hood undergoes rigorous testing before shipment. You receive equipment that complies with demanding regulatory standards for laboratory ventilation.

Our engineering team applies decades of expertise to product development. We integrate advanced safety features while maintaining practical usability for daily operations.

Quality Standards and Certifications

Installation and Customization Options

We offer comprehensive project support from planning through commissioning. Our one-stop approach simplifies procurement and coordination.

Flexible Configuration

Choose from three standard sizes to match your lab footprint. Custom dimensions accommodate specialized equipment or unusual space constraints.

Integrated Systems

We coordinate with your existing HVAC infrastructure. VAV compatibility optimizes energy efficiency while maintaining proper airflow for safety.

Service Integration

Built-in provisions for water, gas, and electrical connections streamline installation. Your contractor benefits from thoughtful design that reduces labor hours.

Frequently Asked Questions

Q:When should I specify 316L over 304 for a stainless steel hood?

A:Specify 316L when your application involves high concentrations of chlorides or saline solutions. The molybdenum content in 316L provides superior resistance to pitting corrosion.

Q:How does this equipment perform in perchloric acid applications?

A:Standard units require modification for perchloric acid work. Specialized versions with internal water-washdown systems and coved troughs prevent accumulation of explosive perchlorate salts.

Q:What face velocity is recommended for optimal safety?

A:Industry standards typically recommend 80 to 100 feet per minute at standard working sash height. Annual ASHRAE 110 testing verifies proper performance.

Q:Can the interior accommodate integrated sinks or service fixtures?

A:Yes, the weldable material allows seamless integration of cupsinks, gas valves, and electrical outlets. This maintains a leak-proof interior while adding functionality.

Q:How should the surface be maintained to prevent rust?

A:Regular cleaning with deionized water and mild detergents works best. Avoid bleach or chloride-based cleaners which can compromise the passive layer and cause staining.

Contact Our Team Today

Our specialists help you select the right configuration for your requirements for Stainless Steel Fume Hood.

Email us at ceo@ukenlab.com.

Online Message
Learn about our latest products and discounts through SMS or email