Economy Fume Hood
1.0 mm cold-rolled steel sheet
Airflow Technology
Adopts multi-duct laminar flow air supply
Make-up air ratio: 60%
Air Volume Parameter
Standard height: exhaust air flow 220-360 m³/h
Qualified air leakage rate, energy-saving
Basic Cabinet Configuration
Standard: two double-door storage cabinets
Support frame-type structural upgrade
Optional Accessories
Fireproof chemical cabinet / waste liquid cabinet / waste bin
Guarantee lab safety & sanitation
Ventilation Connection
Upper & lower cabinets all connectable to exhaust system
- Product Description
Economy Fume Hood: Professional Laboratory Ventilation at an Optimized Price Point
Luoyang Youken Laboratory Equipment brings you a high-performance Economy Fume Hood engineered in our 30,000 m² ISO and CE certified manufacturing facility. Built with robust 1.0 mm cold-rolled steel, this unit delivers essential operator protection without compromising safety standards.
Our design team of 100 professional engineers has developed a multi-duct laminar flow air supply system that achieves standard exhaust air flow of 220-360 m³/h at qualified energy-saving levels. With a 60% make-up air ratio and tapered aerodynamic construction, your lab benefits from reduced noise and stable containment performance. Available in three standard widths—1200mm, 1500mm, and 1800mm—this product serves educational institutions, biotech startups, and quality control facilities requiring OSHA-compliant ventilation at capital-conscious pricing.

Why Choose Our Cost-Effective Laboratory Ventilation Solution
You face real challenges when outfitting a new laboratory or expanding existing facilities. Capital budgets are tight, yet safety cannot be compromised. Our Team understands this balance.
That's why we've engineered this unit to focus on core containment functionality. You get reliable protection from hazardous fumes, vapors, and dust without paying for advanced features your application may not require. The chemical-resistant construction withstands daily exposure to common reagents used in organic chemistry, routine sampling, and titration work.
Standard dimensions allow for rapid deployment. You can integrate these units quickly into your facility layout without extensive customization delays. This speed-to-operation matters when project timelines are compressed or temporary research spaces need immediate compliance with fire codes and laboratory safety regulations.

Technical Specifications
| Parameter | Specification |
|---|---|
| Material | 1.0 mm cold-rolled steel sheet with epoxy coating |
| Airflow Technology | Multi-duct laminar flow air supply |
| Make-up Air Ratio | 60% |
| Exhaust Air Flow | 220-360 m³/h (standard height) |
| Cabinet Configuration | Two double-door storage cabinets (standard) |
| Available Sizes | L1200×D850×H2350 mm |
| L1500×D850×H2350 mm | |
| L1800×D850×H2350 mm | |
| Ventilation Connection | Upper & lower cabinets connect to exhaust system |
| Optional Accessories | Fireproof chemical cabinet, waste liquid cabinet, waste bin |
Superior Material and Chemical Resistance
Your laboratory work demands materials that stand up to daily chemical exposure. We construct each unit from premium cold-rolled steel treated with advanced epoxy coating systems.
This surface treatment provides excellent chemical resistance across a broad spectrum of common laboratory reagents. The tapered internal design does more than reduce air resistance—it minimizes turbulence zones where fumes might escape containment boundaries.
The universal diameter exhaust connections simplify your duct installation. Your facilities team will appreciate the straightforward integration with existing HVAC infrastructure. No custom adapters or complex modifications are needed in most installations.
Smart Cabinet Design for Laboratory Efficiency
Storage matters in busy laboratory environments. Our standard configuration includes two double-door cabinets beneath the work surface.
These compartments provide convenient storage for frequently used materials and equipment. Both upper and lower cabinets connect to your exhaust system, ensuring proper ventilation throughout the entire unit. This integrated approach prevents hazardous vapor accumulation in storage areas.
For specialized requirements, you can upgrade to frame-type structural configurations. This flexibility allows you to adapt the Economy Fume Hood to your specific workflow needs without purchasing an entirely different product line.
Comprehensive Optional Safety Accessories
Laboratory safety extends beyond the fume hood itself. That's why we offer integrated accessories that address your complete safety and sanitation requirements.
Add fireproof chemical cabinets for flammable storage compliance. Install dedicated waste liquid collection systems that prevent spills during disposal procedures. Position waste bins at ergonomic locations to encourage proper laboratory housekeeping practices.
These accessories integrate seamlessly with your base unit. Your laboratory maintains a cohesive appearance while meeting regulatory requirements for hazardous material handling and waste segregation.
Every unit leaving our facility undergoes rigorous quality control protocols. Our team holds certifications from ISO, CE, SEFA, and SGS—your assurance of manufacturing excellence.
We perform containment testing that verifies air leakage rates meet stringent industry standards. Face velocity mapping across multiple measurement points confirms consistent airflow distribution across the work opening. Your operators won't encounter dangerous "dead spots" where fumes escape containment.
Chemical resistance spot tests verify liner durability. Structural components undergo tensile strength verification to ensure long-term mechanical reliability. Airflow visualization using smoke generators confirms our tapered design eliminates vortex-induced turbulence at critical baffle locations.
Global Applications Across Diverse Industries
Our customers deploy these units in pharmaceutical quality control laboratories conducting routine analytical work. Educational institutions choose them for undergraduate chemistry programs where students learn proper Economy Fume Hood operation protocols.
Research and development facilities at biotech incubators rely on our ventilation solutions during capital-intensive startup phases. Food safety laboratories use them for sample preparation and testing procedures. Medical diagnostic labs benefit from the reliable containment during specimen processing.
This versatility comes from our one-stop solution approach. With 100 engineers supporting product development, we've refined designs that serve multiple industry segments without compromising core performance characteristics.

Frequently Asked Questions
Q:Does this hood meet the same safety standards as premium models?
A:Absolutely. It complies with ASHRAE 110 and EN 14175 containment requirements. The difference lies in automation features, not safety performance. You receive OSHA-compliant protection at an optimized price point.
Q:Can I use this unit for highly corrosive acids?
A:Standard configurations handle common laboratory reagents effectively. For specialized applications involving hydrofluoric acid or perchloric acid digestion, consult our engineering team about liner material upgrades to polypropylene or other specialized substrates.
Q:Is the exhaust blower included?
A:Blowers are typically specified separately to match your facility's specific ducting configuration and available static pressure. This approach ensures optimal performance within your building's HVAC parameters.
Q:How often does the unit require airflow certification?
A:Industry best practices recommend annual certification testing. Additional testing is advisable whenever you modify laboratory pressure balance, relocate the unit, or change exhaust system components.
Q:What maintenance does the exterior finish require?
A:The epoxy powder coating provides durable protection in standard laboratory environments. Periodic cleaning with mild detergents maintains appearance. In non-corrosive atmospheric conditions, you can expect 10-15 years of reliable service before refinishing consideration.
Contact Our Laboratory Solutions Team
Our engineering team is prepared to discuss your specific application requirements for Economy Fume Hood and recommend the optimal configuration.