banner

Touchless Lab Faucet

Contact-Free Induction
Infrared sensor water dispensing avoids hand contact and cross-contamination.
Energy & Water Saving
Precise induction for instant on/off, avoiding running water and cutting water consumption.
Smart Sensing Experience
High-sensitivity sensor supports water output even with both hands occupied.
Corrosion Resistance
Acid, alkali and oxidation resistant, adapted to humid and corrosive lab environments.
Stable & Low Maintenance
Rugged structure with low failure rate, easy installation and simple upkeep.
Hygienic & Modern Design
Handleless design leaves no dirt dead corners; sleek look fits modern labs perfectly.
Send Inquiry Download
  • Product Description

Touchless Lab Faucet | Advanced Sensor-Activated Laboratory Faucets 

Luoyang Youken Laboratory Equipment Co., Ltd. conveys a professional-grade Touchless Lab Faucet outlined particularly for high-stakes controlled situations. Made in our 30,000 m² generation office and designed by a group of 100 proficient engineers, this sensor-activated fixture disposes of cross-contamination dangers through infrared detecting technology.

Our item highlights a high-performance solenoid valve appraised for over 1,000,000 cycles, with a quick reaction time of less than 0.5 seconds. Developed from lead-free brass or AISI 316L stainless steel, each unit experiences thorough testing to guarantee compliance with ISO, CE, SEFA, and SGS benchmarks. The IP67-rated waterproof sensor module ensures dependable operation indeed in sticky, destructive research facility conditions.

This hands-free arrangement underpins biosafety conventions in pharmaceutical, therapeutic, and investigate offices around the world. The instinctive plan requires no preparing whereas conveying reliable, touchless operation for upgraded research facility safety.

Touchless Lab Faucet

Core Features & Technical Advantages

Contact-Free Induction Technology

The infrared sensor framework enacts water stream immediately without physical contact. This innovation anticipates pathogen exchange between work force in biosafety level (BSL) environments.

Your lab staff can work the Touchless Lab Faucet even with gloves sullied by chemical buildups. The high-sensitivity sensor identifies hand nearness inside flexible location zones.

Energy & Water Conservation

Precise movement detecting gives moment on/off control that dispenses with water squander. The low-power utilization circuit expands battery life up to 5 a long time in battery-operated models.

This brilliantly water administration decreases operational costs. You'll take note noteworthy reserve funds in offices running ceaseless investigate protocols.

Corrosion-Resistant Construction

Chemical-resistant powder coatings and medical-grade stainless steel withstand presentation to unstable natural compounds (VOCs) and destructive acids. The body fabric passes thorough 24-48 hour salt shower testing.

The streamlined, handleless plan disposes of earth aggregation focuses. This makes schedule cleaning quick and thorough.

Smart Sensing Experience

Stationary question location anticipates wrong actuation from research facility crystal or apparatuses set in the sink. The sensor overlooks objects remaining stationary for more than 30 seconds.

Adjustable sensor ranges oblige diverse sink arrangements. You can customize discovery zones to avoid ghost-activation in intelligent stainless steel environments.

Technical Specifications

ParameterSpecification
Body MaterialLead-Free Brass / AISI 316L Stainless Steel
Sensor TypeInfrared / Capacitive Proximity
Response Time< 0.5 seconds
Solenoid Valve Life> 1,000,000 cycles
Waterproof RatingIP67 (sensor module)
Operating Pressure0.5 - 6.0 bar (7 - 87 PSI)
Pressure Testing125 PSI structural integrity
Power OptionsAC/DC Hybrid with Battery Backup
Battery LifeUp to 5 years (DC models)
Sensor WindowChemical-Resistant Polycarbonate / Sapphire Glass
Temperature ControlThermostatic Mixing Valve (TMV) compatible
Compliance StandardsNSF/ANSI 61, ADA, ISO, CE, SEFA, SGS
Detection RangeAdjustable (5-25 cm typical)
Finish OptionsChemical-Resistant Powder Coating

Application Scenarios

High-Containment Biosafety Laboratories

BSL-3 and BSL-4 offices require supreme sterile field support. Our touchless innovation avoids dangerous pathogen exchange amid basic cleaning procedures.

The fail-safe closure component guarantees control judgment amid control intrusions. Your group keeps up convention compliance indeed amid crisis situations.

Pharmaceutical GMP Cleanrooms

Formulation and washing regions request zero bacterial development openings. The handleless plan disposes of dead spaces where contaminants accumulate.

Frequent sterilization cycles won't corrupt the chemical-resistant surface wraps up. You accomplish reliable execution all through rigid approval periods.

Analytical Chemistry Facilities

Corrosive reagent taking care of requires assurance for both faculty and gear. The touchless interface anticipates chemical buildup exchange from gloved hands to inside mechanisms.

Temperature-controlled water conveyance through thermostatic blending valves guarantees reliable comes about. Your titration and cleaning arrangements keep up exactness standards.

Educational and Research Institutions

Training situations advantage from natural, no-training-required operation. Understudies and analysts center on tests or maybe than spigot operation.

The wide pertinence over chemical, pharmaceutical, and organic research facilities disentangles office standardization. You decrease support complexity over different lab spaces.

Application Scenarios

Quality Assurance & Testing Protocols

Rigorous Inspection Benchmarks

Our fabricating handle actualizes five basic quality control checkpoints. Each Touchless Lab Faucet experiences cycle life testing to confirm 500,000+ operations without failure.

Pressure and spill testing at 125 PSI affirms basic keenness. This surpasses standard research facility plumbing framework requirements.

Material Composition Verification

Spectrometer testing ensures compliance with lead-free controls. We confirm high-grade combination determinations, affirming 316L stainless steel where specified.

Chemical resistance testing uncovered units to laboratory-grade disinfectants counting isopropyl liquor and fade. The sensor windows and wrap up coatings keep up clarity and protection.

Sensor Precision Calibration

Laboratory situations frequently highlight high-frequency lighting and intelligent hardware. Our calibration prepare dispenses with obstructions from these sources.

Detection zone precision testing guarantees steady enactment separations. You get factory-calibrated units prepared for quick installation.

Quality Assurance & Testing Protocols

Installation & Maintenance Support

Streamlined Installation Process

Standard plumbing associations rearrange retrofitting into existing research facility sinks. The compact under-deck gadgets module fits most sink configurations.

Hybrid AC/DC control choices give adaptability for distinctive office foundations. Battery reinforcement frameworks keep up operation amid control fluctuations.

Low-Maintenance Operation

The tough development diminishes disappointment rates altogether. Schedule support includes occasional cleaning of the inline channel to avoid dregs buildup.

This basic method guarantees the solenoid valve keeps up tight fixing and steady stream rates. Your offices group handles upkeep without specialized training.

Emergency Operation Features

Intuitive manual override controls enable fast emergency activation. No training is required for personnel to operate backup systems during sensor failures.

This fail-safe design meets laboratory safety standards for convenient inspection and routine compliance checks.

Frequently Asked Questions

Q:How does the touchless faucet handle power failures during critical experiments?

A:Professional models include manual override functionality and fail-safe closure mechanisms. Hybrid AC/DC configurations with battery backup ensure continuous operation during power interruptions.

Q:Can the sensor window withstand harsh laboratory disinfectants?

A:Yes. High-quality units use sapphire glass or chemical-resistant polycarbonate designed for frequent wipe-downs with isopropyl alcohol, bleach, and other lab-grade disinfectants.

Q:How do you prevent accidental activation from glassware or laboratory tools?

A:Our units feature Stationary Object Detection technology with adjustable sensor ranges. Objects remaining in the sink for more than 30 seconds are ignored by the sensor.

Q:Is water temperature adjustable on these sensor faucets?

A:Temperature is managed via an under-deck thermostatic mixing valve (TMV) that ensures consistent, scald-safe water delivery. The sensor controls flow activation only.

Q:What maintenance schedule should we follow for the solenoid valve?

A:We recommend cleaning the inline filter every 3-6 months depending on water quality. This prevents sediment buildup and maintains optimal valve performance and flow consistency.

Partner With a Trusted Laboratory Solutions Provider

Contact our engineering team at ceo@ukenlab.com to discuss your specific requirements for Touchless Lab Faucet.

Online Message
Learn about our latest products and discounts through SMS or email