Fume Extraction Hood
1.0 mm cold-rolled steel sheet
High-temperature resistant and free from deformation.
Excellent ageing resistance and anti-fading performance.
Widely applicable for various laboratory experiments.
Exquisite packaging prevents damage during shipment.
Stable quality adapts to long-distance transportation.
Possess CE, ISO and CQC authoritative certifications.
- Product Description
Fume Extraction Hood - Industrial-Grade Lab Safety Solution
At Luoyang Youken Laboratory Equipment Co., Ltd., our Fume Extraction Hood is built from premium 1.0 mm cold-rolled steel sheet to convey prevalent execution in requesting situations. Our 30,000 m² fabricating office and group of 100 proficient engineers guarantee each unit meets worldwide ISO, CE, SEFA, and SGS standards.
This item highlights high-temperature safe development with great maturing resistance and anti-fading execution. The effective fan framework, coordinates with fine discuss channel plan, quickly releases destructive gasses, clean, and vapor to ensure your work force. With steady discuss volume yield and moo commotion operation, it underpins persistent long-time utilize over pharmaceutical, therapeutic, chemical, and investigate laboratories.
Our durable structure ensures solid control of harmful substances, avoiding them from entering administrator breathing zones whereas keeping up ideal workspace safety.

Why Choose Our Fume Extraction Hood System?
Laboratory security ought to never be compromised. Your group merits security from dangerous chemical vapors, harmful gasses, and particulate matter.
Our extraction framework tackles basic working environment challenges. You'll accomplish compliance with word related presentation limits whereas anticipating long-term respiratory dangers. The centered capture plan guarantees contaminants never reach breathing zones.
Unlike common ventilation, our Fume Extraction Hood targets emanations at the source. You get exact control over airborne risks with negligible vitality waste.
The cold-rolled steel development withstands destructive situations. Your venture remains ensured through a long time of requesting research facility operations.
Technical Specifications & Parameters
| Parameter | Details |
|---|---|
| Material | 1.0 mm cold-rolled steel sheet |
| Available Sizes | L1200×D850×H2350 mm |
| L1500×D850×H2350 mm | |
| L1800×D850×H2350 mm | |
| Noise Level | <60 dB during operation |
| Temperature Resistance | High-temperature resistant, deformation-free |
| Surface Treatment | Anti-fading, aging-resistant coating |
| Airflow Design | Fine air duct with powerful fan system |
| Operation Mode | Continuous long-time operation supported |
| Certifications | ISO, CE, SEFA, SGS, CQC |
Advanced Engineering Features
Superior Ventilation Performance
The effective coordinates fan makes ideal wind current designs. Fine discuss conduit designing guarantees quick release of dangerous substances.
You'll take note prompt enhancements in discuss quality. Hurtful gasses, tidy particles, and chemical exhaust clear productively from your workspace.
Robust Structural Design
Our 1.0 mm cold-rolled steel development conveys uncommon solidness. The fabric stands up to warm misshapening indeed beneath drawn out high-temperature exposure.
The tough system keeps up steady discuss volume all through operation. You encounter steady execution notwithstanding of prepare demands.
Low commotion yield secures your group from sound-related weakness. Indeed amid expanded shifts, the framework works discreetly in the background.
Chemical Resistance Excellence
The premium coating framework withstands forceful chemicals. Your hood keeps up its appearance and usefulness in spite of every day presentation to destructive agents.
Anti-fading properties guarantee long-term stylish offer. The surface remains professional-looking indeed after a long time of seriously research facility use.
Aging resistance implies less substitutions. You diminish add up to fetched of proprietorship whereas keeping up work environment security standards.
Diverse Application Scenarios
Your Fume Extraction Hood serves multiple critical environments effectively.
Pharmaceutical Laboratories: Handle active pharmaceutical ingredients safely. Control exposure during drug formulation, synthesis, and quality testing procedures.
Chemical Analysis Labs: Manage solvent vapors during titrations, extractions, and sample preparations. Protect analysts from harmful organic compounds.
Electronics Manufacturing: Extract rosin flux fumes during soldering operations. Maintain ESD-safe environments while ensuring operator respiratory protection.
Research Institutions: Support diverse experimental protocols across biology, chemistry, and materials science disciplines safely.
Medical Laboratories: Control formaldehyde exposure during pathology work. Manage xylene vapors in histology departments effectively.
Educational Facilities: Provide student protection during teaching lab sessions. Create safe learning environments for hands-on chemistry education.

Complete One-Stop Laboratory Solutions
Luoyang Youken offers comprehensive laboratory infrastructure beyond extraction systems. Our 30,000 m² production base manufactures complete facility solutions.
You can source laboratory benches, storage cabinets, stainless steel sinks, and safety equipment from one trusted supplier. Our 100 professional engineers provide integrated project support.
We handle planning, design, manufacturing, and installation. This streamlined approach saves you procurement time and coordination headaches.
Our product portfolio covers pharmaceutical GMP facilities, cleanrooms, research institutions, and hospital environments. You receive consistent quality across all equipment categories.

Quality Assurance & International Standards
Every unit undergoes rigorous quality control before shipment. We test face velocity profiles, structural integrity, and containment performance.
Our certifications include ISO for quality management, CE for European compliance, SEFA for laboratory furniture standards, and SGS verification. You receive documented proof of regulatory compliance.
Exquisite packaging protects your investment during transportation. Our stable quality adapts to long-distance shipping requirements without damage risks.
We design solutions following international laboratory concepts combined with continuous innovation. Your facility benefits from cutting-edge safety technology.

Frequently Asked Questions
Q: Should I choose a ducted or ductless system?
A: Ducted hoods provide total evacuation of all contaminants regardless of molecular weight. Ductless hoods offer mobility and energy savings but require specific carbon filter matching for your chemicals.
Q: How often should filters be replaced?
A: Depending on usage, filters generally need replacement every 12-24 months. Replace when pressure drop sensors indicate saturation. We recommend annual DOP testing for verification.
Q: What is the optimal capture distance for effective extraction?
A: Position the hood intake within 2 to 3 times the duct diameter from the emission source. This maintains effective face velocity and ensures proper containment.
Q: Does your system comply with international standards?
A: Yes, our hoods are manufactured and tested according to SEFA 1 and SEFA 8 standards for laboratory furniture and fume hood performance verification.
Q: How can I verify containment effectiveness?
A: Perform a smoke pattern visualization test using a smoke generator. This allows you to observe airflow direction and ensure no turbulence causes fume escape.
Contact Us Today
Our Team is prepared to discuss your specific ventilation requirements for Fume Extraction Hood.
Reach out to us at ceo@ukenlab.com.
