Ducted Fume Hood
Detachable parts for easy upkeep; flexible water, power and gas connection.
Safe & Durable
All-steel corrosion-resistant structure, scratch-proof and easy-to-clean surface; stable synchronous belt lifting.
Efficient & Practical
Rapid harmful gas exhaust, low noise and pressure loss; storage design and various sizes available.
Ergonomic & Safe Operation
User-friendly handles and touch control; equipped with covered sockets and sufficient lighting for electric safety.
- Product Description
Professional Ducted Fume Hood for Maximum Laboratory Safety
Luoyang Youken Laboratory Equipment Co., Ltd. brings you enterprise-grade Ducted Fume Hood arrangements built for prevalent control and unwavering quality. Supported by our 30,000 m² generation base and 100 proficient engineers, our hoods include all-steel corrosion-resistant development outlined to meet universal measures counting ISO, CE, SEFA, and SGS certifications. Each unit conveys fast hurtful gas debilitate with negligible clamor and weight misfortune, guaranteeing your lab environment remains secure and effective. With confront speed consistency assembly ASHRAE 110 conventions and flexible raise astound frameworks for ideal wind stream dissemination, our item gives the control execution your basic applications request. Accessible in three standard sizes to fit assorted workspace necessities, these units combine scratch-proof surfaces with adaptable utility associations for direct establishment and long-term durability.

What Makes Our Ducted Fume Hood Different
Our hoods illuminate genuine research facility challenges that experts confront every day. When you handle unstable natural compounds or conduct exothermic responses, you require outright certainty that contaminants are captured at the source.
Unlike ductless frameworks constrained by channel capacity, our Ducted Fume Hood physically evacuates unsafe discuss from your office. This implies you can work unquestionably with obscure compounds, high-volume dissolvable dissipation, or thermal-generating forms without stressing almost distribution into your breathing zone.
The plan keeps up negative weight relative to your lab space. This designing approach guarantees that indeed if turbulence happens, wind current continuously moves absent from you and toward the deplete system.
Your security isn't cleared out to chance. Each unit experiences thorough approval to confirm control effectiveness some time recently it comes to your facility.
Technical Specifications
| Parameter | Option 1 | Option 2 | Option 3 |
|---|---|---|---|
| External Dimensions (L×D×H) | 1200×850×2350 mm | 1500×850×2350 mm | 1800×850×2350 mm |
| Construction Material | All-Steel Corrosion-Resistant Structure | All-Steel Corrosion-Resistant Structure | All-Steel Corrosion-Resistant Structure |
| Surface Treatment | Scratch-Proof, Easy-to-Clean Coating | Scratch-Proof, Easy-to-Clean Coating | Scratch-Proof, Easy-to-Clean Coating |
| Sash Type | Vertical Rising with Safety Glass | Vertical Rising with Safety Glass | Vertical Rising with Safety Glass |
| Lifting Mechanism | Stable Synchronous Belt System | Stable Synchronous Belt System | Stable Synchronous Belt System |
| Baffle System | Adjustable Rear Baffles | Adjustable Rear Baffles | Adjustable Rear Baffles |
| Utility Connections | Flexible Water, Power, and Gas | Flexible Water, Power, and Gas | Flexible Water, Power, and Gas |
| Control System | Touch Control Panel | Touch Control Panel | Touch Control Panel |
| Safety Features | Covered Sockets, Sufficient LED Lighting | Covered Sockets, Sufficient LED Lighting | Covered Sockets, Sufficient LED Lighting |
Core Performance Advantages
Rapid Exhaust Ventilation ensures contaminants are removed immediately from your work zone. The aerodynamic design minimizes turbulence while maximizing capture efficiency, protecting you from exposure during critical procedures.
Odor Containment goes beyond basic extraction. Our baffle configuration creates uniform airflow patterns that prevent chemical vapors from escaping the enclosure, maintaining a clean breathing environment throughout your laboratory.
Purification of Laboratory Environment happens continuously as the system operates. By expelling contaminated air outside your facility rather than recirculating it through filters, you eliminate accumulation risks and maintain consistently safe conditions.
The all-steel construction withstands aggressive chemicals without degradation. You won't face the premature failures common with inferior materials when working with concentrated acids or bases.

Smart Design Features for Daily Operation
Your workflow matters, which is why we've engineered every interaction point for convenience and safety.
Detachable Components make maintenance straightforward. You can access critical areas without specialized tools or excessive downtime. This modular approach reduces your total cost of ownership significantly.
User-Friendly Handles operate smoothly throughout the sash's travel range. The synchronous belt mechanism provides consistent resistance and eliminates the jerky movement associated with chain-and-sprocket systems.
Touch Control Interface puts all essential functions at your fingertips. Monitor airflow status, adjust lighting intensity, and receive maintenance alerts through an intuitive display that doesn't require extensive training.
Ergonomic Work Surface positions at the optimal height for extended procedures. The flush sill airfoil design at the opening edge prevents turbulent backflow while giving you comfortable access to your experiments.
Integrated Storage Solutions below the work surface keep frequently used equipment within reach. This thoughtful layout reduces the need to move away from the Ducted Fume Hood during active procedures, maintaining containment integrity.
Quality Control You Can Trust
Containment validation forms the foundation of our quality assurance process. Every hood undergoes Face Velocity Profile testing to verify uniform airflow distribution across the sash opening.
Flow Visualization using smoke testing identifies any turbulence or dead zones before shipment. This hands-on verification ensures the aerodynamic theory translates into real-world performance.
We conduct SEFA 8 chemical resistance testing on work surfaces and liner materials. Your hood must withstand 24-hour exposure to concentrated acids and bases without structural compromise or surface degradation.
The manufacturing process happens in our certified facility where 100 professional engineers apply decades of combined expertise. This depth of experience translates directly into build quality you'll appreciate over years of service.
Material selection follows stringent protocols. We source corrosion-resistant steel specifically formulated for laboratory environments where moisture, temperature fluctuations, and chemical exposure create demanding conditions.

Frequently Asked Questions
Q:What ongoing maintenance does your product require?
A:Regular maintenance involves quarterly inspections of the sash mechanism, annual face velocity measurements, and visual checks of the liner for chemical damage. The detachable design makes all these procedures straightforward without requiring specialized service contracts.
Q:How do I know if the hood is operating correctly?
A:Your unit includes a touch control panel that monitors airflow continuously. We recommend annual certification testing following ASHRAE 110 protocols to verify containment performance remains within specification.
Q:Can this hood handle perchloric acid work?
A:Our standard models are designed for general chemical use. Perchloric acid applications require specialized water washdown systems and 316-grade stainless steel liners. Contact our engineering team to discuss custom configurations for this specific requirement.
Q:What role does the sash position play in safety?
A:The sash acts as both a physical barrier and an airflow regulator. Operating with the sash above the design height reduces containment effectiveness and increases energy consumption. Always work with the sash at the marked operating position.
Q:Why choose a ducted system over ductless alternatives?
A:Ducted systems provide absolute containment for all chemical types, including low molecular weight compounds that carbon filters cannot trap effectively. If you work with unknown substances or high vapor volumes, ducted exhaust offers superior protection without filter saturation concerns.
Ready to Enhance Your Laboratory Safety?
Contact Us today at ceo@ukenlab.com to discuss your requirements for Ducted Fume Hood and receive detailed technical documentation.